Products

CDT6-ST

As a specialist of CDT6-ST, CNTD Electric Technology Co., Ltd. can offer you comprehensive selections of goods in this industry.

market@cntd.com

Tel: 18857728107

Whatsapp: 8618857728107

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES

◼t1: The start-up delay range of 0.1s-10min can be set (knob

setting).

◼t2: The conversion time is 0.1s-1s can be set (knob setting).

◼Wi th AC220, AC380, AC/DC12V-240V ul tra-wide opera ting

voltage specifications are optional.

◼The working status of the relay is indicated by an LED indicator.

◼Ultra-small size, only 18mm width, 35mm card rail installation.

Application

◼It is specially used for motor star triangle start-up control, which

can greatly simplify the electrical circuit, facilitate wiring and

reduce costs.

No

ltem

Code

Description

①

Product name

CDT6

Clamp rail type time relay

②

Function code

ST

Star delta start time relay (star triangle start delay)

③

Output the number of contact groups

2

Group 2 conversion

 

④

 

Output contact

10

Output contact 10A

16

Output contact 16A

 

 

 

⑤

 

 

 

Rated operating voltage

M

AC220V

w

AC/DC12V-240V

H

AC380V

A-Z letter combination

Custom voltage

SPECIFIFICATIONS

CDT6-ST

Function

Star Triangle start delay

Power terminal

A1-A2

Rated control power supply voltage

 

W   

(AC/DC12V-240V)

AC/DC 12-240V(50-60Hz)

Power consumption

AC 0.3-2VA/DC 0.1-1.2W

Rated control power supply voltage

M(AC220W)

H (AC380V)

AC 220V,AC 380V(50-60Hz)

Power consumotior

AC max.6VA/1.3W

Allowable fluctuation range of power supply

15%+10%

Power indicator

Green LED

Delay range

Start-up delay:0.1 seconds-10 minutes,conversion delay:0.1s-1s

Setting method

knob

Setting accuracy

10%

Repeatability

0.2%

Temperature fluctuation error

0.05%/℃,at=20℃(0.05%°F,at=68°F)

 

Output contact parameters

Number of contacts

2 sets of conversion contacts

10A

2*10A 250VAC/24VDC

16A

2*16A 250VAC/24VDC

Minimum switching power

500mW

Output relay indication

Red LED

Mechanical life

1×10²

Electrical life (resistive load)

1×10⁵

Reset time

Maximum 200ms

Operating ambient temperature

20℃ ~+55℃

Storage and transportation ambient temperature

35℃ ~+75℃

nstallation method

35mm card rail installation

Dretection leve

IP20

Installation location

Arbitrary

Installation altitude

≤2000m

Pollution level

 

Wiring ability

1×2.5mm²or   2×1.5mm²0.4N-m

Dimensions

90mm×18mm×65mn

Weight

80g

CONTROL OUTPUT DIAGRAM

Function diagramw

Wiring diagram

Shape and size (mm)

A powerful company

CONTACT US