description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES

◼Monitor its own operating voltage (true RMS measurement),

45Hz~65Hz wide frequency measurement.

◼8 kinds of rated voltages are adjustable, suitable for voltages in

various regions of the world.

◼3-phase 3-wire and 3-phase 4-wire specifications are optional.

◼The voltage measurement accuracy is ≤1%.

◼It has an anti-harmonic model, which is optimized for high anti

interference occasions.

◼The working status of the relay is indicated by an LED indicator.

◼Ultra-small size, only 18mm width, 35mm card rail installation.

Application

◼Used  for  equipment  protection  and  control  (tower  cranes,air conditioners,elevators,agricultural  equipment,refrigerated  trucks).

◼Protect the equipment to prevent accidents caused by reverse operation.

◼Normal/emergency  power  switch.

◼Prevent phase disconnection of the power load.

No

tem

Code

Description

①

Product name

CDV6

Voltage monitoring relay

 

 

 

 

②

 

 

 

 

Function code

Eunction code

Overvoltage

Undervoltage

Voltage imbalanc

Action delay

Phase sequence protection

Phase-off

protection

3

 -

 -

 -

 -

 ·

 ·

4

2%...20%

-20%...2%

 -

0.1s.…10s

·

·

5

2%.20%

-20%...2%

8%

0.1s.10s

·

·

6

2%...20%

-20%…2%

5%…15%

2s

·

·

7

 

 

5%.15%

0.1s.…10s

·

·

8

15%

-15%

8%

2s

·

·

③

Output contact

16

Output contact 16A

④

Form

None

Common type

X

Anti-harmonic type

 

⑤

 

Rated operating voltage

Code name

Rated yoltage gear

P

220-230-240-380-400-415-440-460VAC(P-P)

N

127-132-138-220-230-240-254-265VAC(P-N)

SPECIFIFICATIONS

P

N

Function

Monitor L-L voltage (3-phase 3-wire system)

Monitor L-N voltage(3-phase 4-wire system)

Monitoring termina

L1-L2-L3

L1-L2-L3-N

Power supply

L1-L2

L1-N

Rated operating voltage selection

220-230-240-380-400

415-440-460(P-P)

127-132-138-220-230

-240-254-265(P-N)

Measuring frequency range

45Hz-65Hz

Measuring range

76V-552V

101V-318V

Voltage threshold range

2%-20%(rated voltage)

Unbalanced value threshold range

5%-15%

Voltage fixed hysteresis rate

2%

Power indicator

Green LED

Action delay time

0.1s -10s(Adjustable)

Voltage measurement erro

≤1%

Power-on delay time

0.5s

Knob setting accuracy

10%

Reset time

1s

Temperature fluctuation error

0.05%/℃,at=20℃

Output contact

parameters

16A

2*16A 250VAC/24VDC

Minimum switching powe

500mW

Output relay indication

Red LED

Mechanical life

1×10⁷

Electrical life(resistive load)

1×10⁵

Uperating ambient temperature

-20℃ ~+55℃

Storage and transportation ambient ten    L][

-35℃~+75℃

Installation method

35mm card rail installation

Protection level

IP20

Installation location

Arbitran

Installation altitude

≤2000m

Pollution level

2

Wiring ability

1×2.5mm²or   2×1.5mm²0.8N·m

Dimensions

90mm×18mm×65mm

Weight

67g

CONTROL OUTPUT DIAGRAM

Wiring diagram

Panel diagram

Function diagramw

A powerful company

CONTACT US