description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES

◼Monitor its own operating voltage (true RMS measurement),

45Hz~65Hz wide frequency measurement.

◼Two sets of output contacts are used for protection and fault

alarm.

◼8 kinds of rated voltages are adjustable, suitable for voltages in

various regions of the world.

◼3-phase 3-wire and 3-phase 4-wire specifications are optional.

◼The voltage measurement accuracy is ≤1%.

◼Anti-harmonic design, optimized for high anti-interference

occasions.

◼The working status of the relay is indicated by an LED indicator.

◼Ultra-small size, only 18mm width, 35mm card rail installation.

Application

◼Used for equipment protection and control (tower cranes, air

conditioners, elevators, agricultural equipment, refrigerated

trucks).

◼Protect the equipment to prevent accidents caused by reverse

operation.

◼Normal/emergency power switch.

◼Prevent phase disconnection of the power load.

No

tem

Code

Description

①

Product name

CDV6

Voltage monitoring relay

 

 

 

 

②

 

 

 

 

Function code

Functior

code

Overvoltage

Undervoltage

Voltage imbalance

Action delay

Phase sequence protection

Phase-off

protection

3D

 -

 -

 -

 -

 *

 *

4D

2%...20%

-20%...2%

 

0.1s…10s

 *

 *

5D

2%...20%

20%....2%

8%

0.1s...10s

 *

* 

6D

2%…20%

-20%.2%

5%.15%

2s

 *

 *

7D

 

 

5%….15%

0.1s…10s

 *

* 

8D

15%

-15%

8%

2s

 *

* 

③

Output contact

08

Output contact 8A

④

Form

None

Common type

X

Anti-harmonic type

 

⑤

 

Rated operating voltage

Code name

Rated voltage gear

P

220-230-240-380-400-415-440-460VAC(P-P)

N

127-132-138-220-230-240-254-265VAC(P-N)

SPECIFIFICATIONS

P

N

Function

Monitor L-L voltage (3-phase 3-wire system)

Monitor L-N voltage (3-phase 4-wire system)

Monitoring terminal

L1-L2-L3

L1-L2-L3-N

Power supply

L1-L2

L1-N

Rated operating voltage selection

220-230-240-380-400

415-440-460(P-P)

27-132-138-220-230

-240-254-265(P-N

Measuring frequency range

45Hz-65Hz

Measuring range

76V-552V

101V-318V

Voltage threshold range

2%-20%(rated voltage)

Uobalanced value threshold range

5%-15%

Voltage fixed hysteresis rate

2%

Power indicator

Green LED

Action delay time

0.1s -10s(Adjustable)

Voltage measurement error

≤1%

Power-on delay time

0.5s

Knob setting accuracy

10%

Reset time

1s

Temperature fluctuation error

0.05%/℃,at=20℃

Output contact

parameters

8A

2*8A 250VAC/24VDC

Minimum switching power

500mW

Output relay indication

Red LED

Mechanical life

1×10′

Electrical life (resistive load)

1×10⁵

Operating ambient temperature

-20℃ ~+55℃

Storage and transportation ambient

re

-35℃~+75℃

nstallation method

35mm card rail installation

Protection level

IP20

loetallation locatior

Arbitrary

nstallation altitude

≤2000m

Pollution level

2

Wiring ability

1×2.5mm²or   2×1.5mm²0.8N-m

Dimensions

90mm×18mm×65mm

Weight

67g

CONTROL OUTPUT DIAGRAM

Wiring diagram

Panel diagram

Function diagram

A powerful company